When a health inspector or an insurer asks whether your pool was being looked after, the water log is the answer. Not the chemistry itself, which only exists in the moment, but the record that someone tested it, wrote down a number, and did something when the number was wrong.

This post sets out what that record should contain, using CDC’s Model Aquatic Health Code, 5th edition (the MAHC) as the reference. The MAHC is guidance, not federal law. It only becomes law where a state or local jurisdiction adopts it, and many adopt it with changes. Treat the numbers below as a benchmark, and check them against the code your inspector actually uses.

The numbers an operator is expected to hold

These are the limits in the MAHC for water chemistry at public aquatic venues:

ParameterMAHC requirement
Free chlorine, pool without cyanuric acidAt least 1.0 ppm at all times
Free chlorine, pool with cyanuric acidAt least 2.0 ppm
Free chlorine, spaAt least 3.0 ppm
Free chlorine, maximumThe limit on the product label
Bromine, poolAt least 3.0 ppm
Bromine, spaAt least 4.0 ppm
Bromine, maximum8.0 ppm while open to bathers
pH7.0 to 7.8
Total alkalinity60 to 180 ppm
Combined chlorineAct to reduce it when it exceeds 0.4 ppm
Cyanuric acidAt or below 90 ppm, and the pool stays closed at 300 ppm or higher until fixed
Calcium hardnessNot above 2,500 ppm
Water temperatureNot above 104°F (40°C)

Free chlorine is measured by the DPD method. The MAHC also says treatment chemicals must be certified to NSF/ANSI 50 or 60 and that disinfectants must be EPA registered and used only according to the manufacturer’s instructions.

Other guidance uses slightly different ranges. CDC’s Legionella toolkit for hot tubs, for example, lists free chlorine of 3 to 10 ppm, bromine of 4 to 8 ppm and pH of 7.2 to 7.8 as control limits. If your local code or manufacturer sets a different range, use that range and write it on the log.

How often to test

The MAHC sets minimum testing frequencies. Free chlorine or bromine and pH must be tested at every venue before opening each day. After that:

  • Manual feed systems (an erosion feeder or metering pump with no automated controller): test before opening and every 2 hours while open.
  • Automatic feed systems: test before opening and every 4 hours while open.
  • In-line ORP readings, if installed: record them at the same time as the chlorine and pH tests.
  • Total alkalinity: weekly.
  • Calcium hardness: monthly.
  • Cyanuric acid: monthly where it is used, and 24 hours after it is added. Weekly if stabilized chlorine is the main disinfectant.
  • Saturation index: monthly.
  • Total dissolved solids: quarterly.
  • Water temperature: recorded alongside the chlorine and pH tests for heated venues.
  • Salt: weekly where in-line electrolytic chlorinators are used.

For hot tubs, CDC’s Legionella guidance goes further: test disinfectant residual and pH at least twice per day, and as often as hourly when in heavy use.

A hotel with a pool open from 7am to 10pm and a manual feed system is looking at roughly eight chlorine and pH tests a day. That is the reason many properties install automated controllers, and the reason a quick log entry matters.

What each log entry should contain

The MAHC lists what daily water monitoring and testing records must include. In practice, one entry per test round should capture:

  1. Venue: pool, spa, kiddie pool, each named separately.
  2. Date and time of the test, recorded when it is done.
  3. Who tested, by name.
  4. Free chlorine or total bromine and pH, as numbers.
  5. Combined chlorine, where it is measured.
  6. Water temperature for heated venues.
  7. Cyanuric acid, alkalinity, calcium hardness and the other periodic tests on their own dates.
  8. Operating pressures of the recirculation pumps and filters, or the flow rate from the flow meter.
  9. Equipment problems and calibration, including dates and times.
  10. What was done: chemical added, backwash done, venue closed and reopened.

The MAHC also expects a chemical inventory log that lists the chemicals used on the water and the deck, including the expiry dates of the test reagents. Expired reagents give wrong numbers, and a wrong number in the log is worse than none.

Record the number, not a tick

The most common weakness in pool logs is the tick. A box labelled “chlorine OK” tells an inspector nothing. A reading of 1.4 ppm at 9:05am, 1.1 ppm at 11:05am and 0.7 ppm at 1:05pm tells them the chlorine was falling through the day and that someone should have acted before 1pm.

A numeric log also lets you see patterns: a pool that drops on every busy weekend, a spa that needs more shocking after check-out day, a controller probe that drifts. Those show up in a column of numbers, not a column of ticks.

What to do when a number is wrong

Write the action beside the reading. If free chlorine is below the minimum, the entry should say what was added, when it was retested and what the new reading was. If the reading cannot be brought into range, the entry should say the pool was closed, by whom, and when it reopened.

A log full of in-range numbers every single time is less believable than one that shows a problem and a fix.

How long to keep it

The MAHC says facility operation records should be kept for a minimum of 3 years and made available on request to the health authority. Local rules may set a different period, and your insurer may ask for longer. Keep the water log with the daily inspection log, incident reports and equipment records so that one request produces everything.

If you move to a digital log, check how long the system keeps history and whether you can export a copy.

Who should be testing

Pool water chemistry should be done by a trained qualified operator, or by staff the operator has trained and supervises. Cleaning contractors should not take on pool testing or chemical handling unless the contract says so and they are trained for it. If your contractor cleans the deck and changing rooms, keep their records separate from the water log, and keep both in the same system so you can answer questions about the whole pool area in one place.

How TidyTrack fits in

TidyTrack can hold the water log as a checklist on a QR poster at the equipment room or pool gate. The tester scans, enters free chlorine, pH and temperature as numbers with the acceptable range beside each, and submits. The time comes from the server, the area from the code and the name from the person logging. A reading outside the range raises an issue, and schedules flag a round that was not logged. Paid plans add CSV export and longer report history for keeping your own copy. It supports your operator. It does not replace an automated controller, test kits or the operator’s judgement. For the wider daily check, read why 1 in 8 pool inspections ends in a closure, and see how the same approach works for fitness clubs with pool decks.